aws logo
header text
       

 

 
Notes:
 
The servicability values shown left are based on 1/150 maximum allowable metal deflection. Windows have been tested for compliance with AS2047. Numbers relate to the jamb locking double sash designs 502, 504 and 506. Significantly higher ratings can be achieved with the centre locking meeting stiles. Also consider Magnum™ sliding windows.
 
VANTAGEDESIGN
SLIDING WINDOWS

Meeting Stile Strength - Jamb Locking
Double sash designs 502, 504 and 506
Single sash designs 501and 503 are shown on previous page.

Meeting Stiles: The limiting strength factor on sliders without lowlights will be the strength of the meeting stiles. The tables below show how the strength of windows will change as the meeting stiles change.

Transoms: On frames fitted with overlights (transoms) the transom will in most cases be the weak link. Refer following page for transom options. For centre locking windows go to next page.
Sliding Window Ratings
Two panel windows type 'SF' and 'FS'

Frame
Height

Frame
Width

Light
Rating

Medium
Rating

Heavy
Rating

1300

1210

545Pa

1226Pa

2067Pa

1300

1510

-

1026Pa

1731Pa

1300

1810

-

908Pa

1531Pa

1400

1210

-

1038Pa

1751Pa

1400

1510

-

863Pa

1455Pa

1400

1810

-

756Pa

1275Pa

1500

1210

-

891Pa

1503Pa

1500

1510

-

736Pa

1242Pa

1500

1810

-

640Pa

1080Pa